Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 111(1): 115-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15367781

RESUMO

The use of episcleral plaques containing radioactive 125I seeds for brachytherapy treatment of selected retinoblastoma cases of patients is being done in Riyadh, Saudi Arabia since 1994. There are about three to four patients per year. A total of 31 patients were treated with a tumour dose in the range of 40-60 Gy using 8 seeds of 125I each from 1994 to 2002. This study determines the trend of occupational doses received by surgeons, anaesthesiologists and nurses and the dose rate profile around the eyes. Only 3% of the 275 persons monitored for Hp(10) have measurable doses with a weighted average of 4 microSv and 7% of the 175 persons monitored for Hp(0.07) have measurable doses with a weighted average of 0.3 mSv. The dose rate is maximum (110 microSv h(-1)) at the point of contact with the eye plaque and reduces to approximately 40% on the side of the other eye.


Assuntos
Braquiterapia/estatística & dados numéricos , Cuidadores , Cuidado da Criança , Neoplasias Oculares/radioterapia , Pessoal de Saúde , Cuidado do Lactente , Radioisótopos do Iodo/uso terapêutico , Exposição Ocupacional , Retinoblastoma/radioterapia , Braquiterapia/instrumentação , Braquiterapia/métodos , Pré-Escolar , Olho/efeitos da radiação , Neoplasias Oculares/enfermagem , Ouro , Humanos , Lactente , Recém-Nascido , Doses de Radiação , Radiometria/instrumentação , Dosagem Radioterapêutica , Retinoblastoma/enfermagem , Arábia Saudita , Pele/efeitos da radiação
2.
Radiat Prot Dosimetry ; 103(2): 169-72, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12593437

RESUMO

The administration of intravenous contrast media by hand or power injection in paediatric computed tomography (CT) procedures is carried out at King Faisal Specialist Hospital and Research Centre for chest, abdomen and torso diagnostic examinations. Some procedures require the CT unit to commence patient scanning during the injection of the last volume of the contrast medium. During the injection, even if the nurse is wearing a 0.5 mm lead equivalent protective apron, the head region and the hand are likely to receive high doses. This study was therefore made to assess the head and extremity doses to the nurses during CT procedures where typical exposure parameters of 200 to 220 mA s and 120 kVp were used. Thermoluminescence dosemeters were deployed for three consecutive months in two CT rooms. A total of 96 procedures were performed during this period and they were included in this study. Scattered radiation measurements were done at different locations where the nurse may be positioned. Results showed that the average dose to the head region and the hands per paediatric case were 50 microSv and 80 microSv respectively. This study investigated the factors that affect the dose and found them to be the length of stay inside the room, type of CT examination. exposure parameters and location of the nurse.


Assuntos
Meios de Contraste/administração & dosagem , Enfermeiras e Enfermeiros , Exposição Ocupacional , Tomografia Computadorizada por Raios X , Adulto , Criança , Mãos/efeitos da radiação , Cabeça/efeitos da radiação , Humanos , Injeções Intravenosas , Imagens de Fantasmas , Roupa de Proteção , Doses de Radiação , Proteção Radiológica , Arábia Saudita , Espalhamento de Radiação , Dosimetria Termoluminescente , Fatores de Tempo , Tomografia Computadorizada por Raios X/enfermagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...